Hyundai Tucson: Automatic Transaxle Control System / Line Pressure Control Solenoid Valve Specifications

Specifications
Direct control VFS[LINE Pressure]
x Control type : Normal high type
Control Pressure kpa (kgf/cmx, psi)
500.14 ~ 9.81
(5.1 ~ 0.1,72.54 ~ 1.42)
Current value(mA)
50 ~ 850
 Internal resistance(x)
5.1

Line Pressure Control Solenoid Valve Description and Operation
Description line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Valve Schematic Diagrams
Circuit Diagram ...

Other information:

Hyundai Tucson (LM) 2010-2015 Service Manual: Positive Crankcase Ventilation (PCV) Valve Repair procedures
Removal 1. Disconnect the vapor hose (A). 2. Remove the PCV valve (B). Inspection 1. Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.     • If the plunger does not move (PCV valve is clogged), clean or re ...