Specifications |
Item | Specification |
Ultrasonic sensor | Voltage rating | DC 12 V |
Detecting range | 15.7 ~ 47.2 in (400 ~ 1200 mm) |
Operation voltage | DC 9 ~ 16 V |
Operation current | MAX 300 mA |
Operation temperature | -22°F ~ + 176°F (-30°C ~ + 80°C) |
Beam width | Horizontal : 100±5°(70cm), Vertical : 60±5°(50cm) |
Number of sensors | 4 (Right, Center-left, Center-right, Left) |
Piezo buzzer | Voltage rating | DC 12 V |
Operation voltage | DC 9 ~ 16 V |
Operation temperature | -22°F ~ + 176°F (-30°C ~ + 80°C) |
Operation current | MAX 60 mA |
Sound, tone | Oscillation frequency : 2.2±0.5 KHz |
Sound level : MIN 70 dB (DC 13V /m) |
Hyundai Tucson (LM) 2010-2015 Service Manual: Rear combination lamp Repair procedures
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Loose the screws (2EA) holding the rear combination lamp then
disconnect the connector (A) then remove the outside rear combination
lamp (B).
3.
Turn the socket counterclockwise to remove the tail/stop lamp bulb (A) and turn ...
Hyundai Tucson (LM) 2010-2015 Service Manual: Repair procedures
Inspection
1.
Disconnect the ignition switch connector (B) and key warning switch connector (A) from under the steering column.
2.
Check for continuity between the terminals.
3.
If continuity is not specified, replace the switch.
Removal
1.