Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the steering column upper and lower shrouds (A) after removing 3 screws.

   
Take care not to damage and scratch the shrouds and its related parts.
Take care not to damage the hook when removing the upper and lower shrouds.
3.
Disconnect the light switch connector (A) and the wiper switch connector (B).
[LHD]

[RHD]

[LHD]

[RHD]

4.
Remove the wiper switch (A) by pushing the lock pin (B).
   
When removing the wiper & washer switch only, release the lock of wiper switch without removing the steering wheel.

Installation
1.
Install the multifunction switch.
2.
Install the clock spring and steering wheel.
3.
Install the steering column upper and lower shrouds.
Inspection
Check for continuity between the terminals while operating the wiper and washer switch. If it is not normal condition, replace wiper and washer switch.
[LHD]

[RHD]

Wiper Switch

Washer Switch

Rear Wiper Switch

Rear Washer Switch

Components and Components Location
Component Location 1. Windshield wiper arm & blade2. Wiper & washer switch3. Windshield washer hose4. Windshield wiper motor & linkage5. Washer motor (Front)6. Washer reservoir7. Wash ...

Front Wiper Motor Components and Components Location
Component Location 1. Cap2. Nut3. Wiper arm & blade4. Retainer5. Cowl top cover6. Bolt7. Wiper motor & linkage assembly8. Wiper motor connector ...

Other information:

Hyundai Tucson (LM) 2010-2015 Service Manual: Accelerator Position Sensor (APS) Repair procedures
Inspection 1. Connect the GDS on the Data Link Connector (DLC). 2. Turn the ignition switch ON. 3. Measure the output voltage of the APS 1 and 2 at C.T and W.O.T. Specification: Refer to “Specification” Removal 1. Turn the ignition switch OFF and disconnect the negative ...

Hyundai Tucson (LM) 2010-2015 Service Manual: Positive Crankcase Ventilation (PCV) Valve Repair procedures
Removal 1. Disconnect the vapor hose (A). 2. Remove the PCV valve (B). Inspection 1. Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.     • If the plunger does not move (PCV valve is clogged), clean or re ...