Hyundai Tucson: Air Conditioning System / Ambient Sensor Description and Operation

Description
1.
The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperatures.
2.
The sensor output will be used for discharge temperature control, temperature regulation door control, blower motor level control, mix mode control and in-car humidity control.
   
If the ambient temperature is below 2.0°C (35.6°F), the A/C compressor will be stopped.
The compressor will be operated by manual operating.
Photo Sensor Repair procedures
Inspection 1. Ignition "ON" 2. Using the scan tool. 3. Emit intensive light toward photo sensor using a lamp, and check the output voltage change. 4. The voltage will rise with higher ...

Ambient Sensor Repair procedures
Inspection 1. Ignition "OFF" 2. Disconnect ambient temperature sensor. 3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing o ...

Other information:

Hyundai Tucson (LM) 2010-2015 Service Manual: Rear Glass Defogger Switch Repair procedures
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the right air vent. (Refer to BD group - "Crash pad") 3. Remove the rear glass defogger switch (A). [LHD] [RHD]     Take care not to damage the hook when removing the rear glass defogger switch. I ...

Hyundai Tucson (LM) 2010-2015 Service Manual: Schematic Diagrams
ESC connector input/output Connector TerminalSpecificationRemarkNoDescription29IGNITION1(+)High level of wake up voltage :5.0V < V < 16.0VLow level of wake up voltage V < 2.4VMax. current : I < 50mAx25POS. BATTERY 1.(SOLENOID)Over voltage range : 17.0 ± 0.5V Operating voltage range ...