Description |
Item | Standard value |
Rate voltage | DC 12V |
Operating voltage range | DC9 ~ 16V |
Operating temperature range | -30 ~ +65°C (-22 ~ 149°F) |
Direction display | 8 |
Renewal time | 2 sec. |
Switch point | Heading ± 10° |
N - NE | 22.5 |
NE - E | 67.5 |
E - SE | 112.5 |
SE - S | 157.5 |
S - SW | 202.5 |
SW - W | 247.5 |
W - NW | 292.5 |
NW - N | 337.5 |
There should be hysteresis at each switch point.
Switch points between the 8 cardinal directions, these switch points are ± 10° |
Function |
1. |
Press and release the feature control button (A) to turn the display feature OFF. |
2. |
Press and release the feature control button (A) again to turn the display back ON.
Additional options can be set with press and hold sequences of the feature control button (A) and are detailed below.
There is a difference between magnetic north and true north.
The compass in the mirror can compensate for this difference when it
knows the magnetic zone in which it is operating. This is set either by
the dealer or by the user. |
Hyundai Tucson (LM) 2010-2015 Service Manual: Injector Troubleshooting
Signal Waveform
The three waveforms below are taken from the #1 and #4
injectors. The top waveform is from the high side (feed side) of the #1
and #4 injectors, while the middle waveform is from the low side (ground
side) of the #1 injector and the bottom waveform is from the low side
of ...
Hyundai Tucson (LM) 2010-2015 Service Manual: Relay Box (Passenger Compartment) Description and Operation
Description
SJB (Smart Junction Box)
1.
Specification
ItemRequirementRemarkRated voltageDC 12VxVoltage rangeDC 8 ~ 16VNormal operating in this rangeStorage temperature-40°C ~ +95°CxOperating temperature-30°C ~ +85°CxOperating humidity85%PCB, Damp proofing, Coating, etc.Dark currentMax. 2 ...