Hyundai Tucson: Engine Control System / Heated Oxygen Sensor (HO2S) Specifications

Specification
HO2S [Bank 1/Sensor 1] (Linear type)
Item
Specification
Heater Resistance (x)
2.4 ~ 4.0 [20°C(68°F)]

HO2S [Bank 1/Sensor 2] (Binary type)
A/F Ratio (x)
Output Voltage(V)
RICH
0.6 ~ 1.0
LEAN
0 ~ 0.4

Item
Specification
Heater Resistance (x)
Approx. 9.0 [20°C(68°F)]

Heated Oxygen Sensor (HO2S) Description and Operation
Description Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Manifold Catalytic Converter. The sensor output voltage varies in ...

Heated Oxygen Sensor (HO2S) Schematic Diagrams
Circuit Diagram (M/T) (A/T) ...

Other information:

Hyundai Tucson (LM) 2010-2015 Service Manual: Refrigerant line Repair procedures
Replacement 1. Discharge refrigerant from refrigeration system. 2. Replace faulty tube or hose.     Cap the open fittings immediately to keep moisture or dirt out of the system. 3. Tighten joint of bolt or nut to specified torque.     Connections s ...

Hyundai Tucson (LM) 2010-2015 Owners Manual: Mode selection
The mode selection button controls the direction of the air flow through the ventilation system. Air can be directed to the floor, dashboard outlets, or windshield. Six symbols are used to represent the direction and flow of ventilation: MAX A/C, Face, Bi-Level, Floor, Floor- Defrost and ...