Hyundai Tucson: General Information / Specifications

Specifications
Purge Control Solenoid Valve (PCSV)
x Specification
Item
Specification
Coil Resistance (x)
22.0 ~ 26.0 [20°C(68°F)]

Fuel Tank Pressure Sensor (FTPS)
x Type: Piezo-Resistive Pressure Sensor
x Specification
Pressure [kPa (kgf/cmx, in H2O)]
Output Voltage (V)
-6.67 (-0.068, -26.8)
0.5
0
2.5
+6.67 (0.068, 26.8)
4.5

Canister Close Valve (CCV)
x Specification
Item
Specification
Coil Resistance (x)
19.8 ~ 21.8 [20°C(68°F)]

Tightening Torques
Item
kgf.m
N.m
lb-ft
Positive crankcase ventilation valve installation
0.2 ~ 0.3
1.96 ~ 2.94
1.45 ~ 2.17
Canister installation bolt
0.4 ~ 0.6
3.9 ~ 5.9
2.9 ~ 4.3
Fuel tank air filter installation bolt
0.4 ~ 0.6
3.9 ~ 5.9
2.9 ~ 4.3

Description and Operation
Description Emissions Control System consists of three major systems. • The Crankcase Emission Control System prevents blow-by gas from releasing into the atmosphere. This system recycles g ...

Troubleshooting
Troubleshooting SymptomSuspect areaEngine will not start or hard to startVapor hose damaged or disconnectedEngine hard to startMalfunction of the Purge Control Solenoid ValveRough idle or engine ...

Other information:

Hyundai Tucson (LM) 2010-2015 Service Manual: 35R Clutch Control Solenoid Valve(35R/C_VFS) Specifications
Specifications Direct control VFS[35R/C] x Control type : Normal high type Control Pressure kpa (kgf/cmx, psi) 500.14 ~ 9.81(5.1 ~ 0.1, 72.54 ~ 1.42)Current value(mA)50 ~ 850 Internal resistance(x)5.1 ...

Hyundai Tucson (LM) 2010-2015 Service Manual: Valve Body Description and Operation
Description The valve body is essential to automatic transaxle control and consists of various valves used to control the oil feed from the oil pump. Specifically, these valves consist of pressure regulator valves, oil redirection valves, shift valves, and manual valves. ...

© 2010-2021 www.htmanual.net